OYOSTEPPER Products is pleased to announce the release of holding brakes for select step motors in the NEMA 23 frame size. These step motors provide additional functionality for applications which require holding torque to be maintained when power is removed from the motor.
Holding brakes offered by OYOSTEPPER are spring-set type brakes that must be powered by 24 volts DC to release the brake mechanism. This is commonly referred to as “power off” and is the preferred style for motion control applications. Controlling the brake is handled by a discrete output on the stepper drive or another controller like a PLC or motion controller. Many OYOSTEPPER drives offer outputs specifically designed to control the holding brake, such that the brake will be automatically engaged whenever the motor is unpowered (and automatically disengaged when the motor is powered or moving).
This initial offering of holding brakes for step motors is available as an option on the following most popular NEMA 23 frame step motors. Click to view specifications and pricing:
HT23-594B
HT23-598B
HT23-601B
HT23-603B
A common application for holding stepping motor brake is one in which a belt drive linear actuator is mounted vertically. When power is removed from the motor the belt and load can drop, potentially causing harm to the machine and/or human operators. Holding brakes can help to alleviate this unsafe condition by automatically holding the motor and load in position even when all power has been removed from the motor.
mercredi 11 juillet 2018
jeudi 7 juin 2018
Basics of Stepper Motors You Should Know
Operation & Structure
A stepper motor rotates with a fixed step angle, just like the second hand of a clock. Highly accurate positioning can be performed with open-loop control thanks to the mechanical structure within the motor.
Accurate Positioning (Number of Steps)
While having full control of rotation and speed, the simple structure of stepper motors is achieved without using electrical components, such as an encoder within the motor. For this reason, stepper motors are very robust and have high reliability with very few failures. As for stopping accuracy, ±0.05° (without cumulative pitch errors) is very accurate. Because positioning of stepper motors is performed by open-loop control and operated by the magnetized stator and magnetic rotor with small teeth, stepper motors have a higher follow-up mechanism toward commands than that of servo motors. Also, no hunting occurs when stopping stepper motors. They are also excellent in belt drives, which have low rigidity.
Useful for Speed Control and Position Control
When pulses are input to a driver through a pulse generator, stepper motors position according to the number of input pulses. The basic step angle of 5-phase stepper motors is 0.72° and 1.8° stepper motor for 2-phase motors. The rotating speed of the stepper motor is determined by the speed of the pulse frequency (Hz) given to the driver, and it is possible to freely change the motor rotation by simply changing the number of input pulses or frequencies to the driver. Stepper motors not only serve as position control motors, but also as speed control motors with high synchronization.
Stepper Motors Uses:
• High frequency, repetitive positioning of fixed step angles
• Positioning that requires long stopping time due to width adjustment, etc.
• Fluctuating loads and changing rigidity
• Positioning that divides 1 cycle
• Motor shafts that requires synchronous operation
See more:https://www.oyostepper.com/
A stepper motor rotates with a fixed step angle, just like the second hand of a clock. Highly accurate positioning can be performed with open-loop control thanks to the mechanical structure within the motor.
Accurate Positioning (Number of Steps)
While having full control of rotation and speed, the simple structure of stepper motors is achieved without using electrical components, such as an encoder within the motor. For this reason, stepper motors are very robust and have high reliability with very few failures. As for stopping accuracy, ±0.05° (without cumulative pitch errors) is very accurate. Because positioning of stepper motors is performed by open-loop control and operated by the magnetized stator and magnetic rotor with small teeth, stepper motors have a higher follow-up mechanism toward commands than that of servo motors. Also, no hunting occurs when stopping stepper motors. They are also excellent in belt drives, which have low rigidity.
Useful for Speed Control and Position Control
When pulses are input to a driver through a pulse generator, stepper motors position according to the number of input pulses. The basic step angle of 5-phase stepper motors is 0.72° and 1.8° stepper motor for 2-phase motors. The rotating speed of the stepper motor is determined by the speed of the pulse frequency (Hz) given to the driver, and it is possible to freely change the motor rotation by simply changing the number of input pulses or frequencies to the driver. Stepper motors not only serve as position control motors, but also as speed control motors with high synchronization.
Stepper Motors Uses:
• High frequency, repetitive positioning of fixed step angles
• Positioning that requires long stopping time due to width adjustment, etc.
• Fluctuating loads and changing rigidity
• Positioning that divides 1 cycle
• Motor shafts that requires synchronous operation
See more:https://www.oyostepper.com/
lundi 7 mai 2018
The Motor Encoder: When Closed Loop Control is Essential
An stepper motor encoder for sale is a rotary device that can be mounted onto an electric motor. It provides closed loop feedback signals, tracking the motor shaft’s position, speed, or both.
At first, this functionality might seem redundant. Isn’t precision control essentially what the stepper does on its own? The answer, it seems, is yes and no. Recent research has shown that the apparently “unnecessary” guidance provided by the encoder can have a powerful impact on how well a stepper motor works.
Motion controller brand Galil conducted a series of side by side tests between open and closed loop stepper motor systems. Their team discovered that the addition of an encoder could produce appreciable gains in major performance metrics.
Compared to the open loop system, the closed loop stepper motor offered:
Significantly improved velocity smoothness;
Reduced overall current consumption;
Higher torque at lower velocities than comparable three-phase brushless servo motors.
Galil's researchers determined that “dramatic” performance gains for stepper motors were possible by integrating a positional feedback device along with a two-phase brushless amplifier. Their testing methodology and results have been made public on their website.
These results are truly exciting news in the motion control world. Engineers at all levels can enhance stepper motors into even more powerful and economical solutions through the use of readily available encoder technologies.
KNOWLEDGE of CLOSED LOOP STEPPER SERVOS FOR EVERYONE
At first, this functionality might seem redundant. Isn’t precision control essentially what the stepper does on its own? The answer, it seems, is yes and no. Recent research has shown that the apparently “unnecessary” guidance provided by the encoder can have a powerful impact on how well a stepper motor works.
Motion controller brand Galil conducted a series of side by side tests between open and closed loop stepper motor systems. Their team discovered that the addition of an encoder could produce appreciable gains in major performance metrics.
Compared to the open loop system, the closed loop stepper motor offered:
Significantly improved velocity smoothness;
Reduced overall current consumption;
Higher torque at lower velocities than comparable three-phase brushless servo motors.
Galil's researchers determined that “dramatic” performance gains for stepper motors were possible by integrating a positional feedback device along with a two-phase brushless amplifier. Their testing methodology and results have been made public on their website.
These results are truly exciting news in the motion control world. Engineers at all levels can enhance stepper motors into even more powerful and economical solutions through the use of readily available encoder technologies.
KNOWLEDGE of CLOSED LOOP STEPPER SERVOS FOR EVERYONE
vendredi 4 mai 2018
Why stepper motors? What about other types of motors?
Choosing an appropriate stepper motor such as nema size 17 can be difficult and time consuming. This webpage is intended to help you easily and quickly select a good stepper motor for your project. There is a lot to cover, so consider this the first part in the series.
Why stepper motors? What about other types of motors?
Stepper motors online are by far the most common types of motors used for CNC Machines. Stepper motors have a unique property that makes them particularly well suited for CNC motion. Each time a stepper motor receives a pulse, it only moves a certain amount. For a full step, this is usually 1.8 degrees and for a half-step this is usually 0.9 degrees. The reason this is important is because the computer running the motor doesn’t need to sense the actual position of the motor because the motor’s position can be calculated solely by how many pulses have been sent out.
Another possibility is to use PWM motors. These motors produce different torque depending on the duty cycle of a square wave signal it receives. However, a more complicated controller and an expensive quadrature encoder must be used to determine the current location of the motor at all times. This is a closed loop control system, where the system reacts based on position data which is detected through a sensor.
Why stepper motors? What about other types of motors?
Stepper motors online are by far the most common types of motors used for CNC Machines. Stepper motors have a unique property that makes them particularly well suited for CNC motion. Each time a stepper motor receives a pulse, it only moves a certain amount. For a full step, this is usually 1.8 degrees and for a half-step this is usually 0.9 degrees. The reason this is important is because the computer running the motor doesn’t need to sense the actual position of the motor because the motor’s position can be calculated solely by how many pulses have been sent out.
Another possibility is to use PWM motors. These motors produce different torque depending on the duty cycle of a square wave signal it receives. However, a more complicated controller and an expensive quadrature encoder must be used to determine the current location of the motor at all times. This is a closed loop control system, where the system reacts based on position data which is detected through a sensor.
dimanche 27 décembre 2015
The Detail Function of SBB Key Programmer
In this modern society, we need to catch up with the pace of this high-tech world by
updating our knowledge. Have you noticed that the best car key programmer –
SBB Key Programmer has launched a new version into the market? If you’ve never
heard about this popular SBB Key Programmer V33 Version ever before, maybe
you really need to read this article carefully.Today tool supplier –obd2works.com
will help you and give you the detail information about those outstanding functions
of it.
Firstly, silica sbb transponder key machine is a new device used as a portable unit for
programming keys in immobilizer units on vehicles. And due to its integrated hardw
are, this best obdii–SBB needs no more than the OBDII cable provided to carry
out a wide range of functions. Secondly, programming new keys and reading keys from
immobilizers memory,deactivating keys no longer in the car owners possession are
available too. Operation by means of a menu guided programming and programming
new remote controls are its features, too. Moreover the software consists of full
database containing all the most important vehicle makes. What’s delighted, It can
supports many foreign languages, for this newest version, the supported languages
exactly includes Italian/German/French/English/Spanish/Greek/Portuguese/
Turkish/Russian. And the supported cars are Multi-brands.
More detail information can be found on obd2works.com,and there are more car diagn
ostic products you will be interested in.Any problem please feel free to contact us,we
will try our best to meet your demands.(digiprog3 4.94)
dimanche 27 septembre 2015
KWP2000 Plus fonctionne bien pour Peugeot 206 HDI
Je ai récemment acheté un kit d'un KWP2000 Plus pour se adapter à mon 2001 Peugeot 206 Turbo 90 ch 2.0HDI, afin de redéfinir pour augmenté ch. Commande passée le 26 Novembre, expédiée le lendemain et est arrivé à mon magasin ce matin.

Je ai mis mes KWP2000 plus écus Remap Flasher de obd2warehouse.fr. Il est venu avec un mini CD, contenant son logiciel. Le vendeur a déclaré le logiciel doit être installé sur XP. Je ne ai aucun problème d'installation sur un ordinateur XP et je ai ensuite réussi à utiliser sur mon ordinateur portable Windows 7 en utilisant VM ainsi. Hooked on jusqu'à ma voiture quelques minutes après l'arrivée et reconfiguré mon écus. Il a travaillé comme il se doit.
Voici un processus rapide à propos de flashage écus avec KWP2000:
- Brancher le matériel sur le port USB de l'ordinateur portable et le port de diagnostic de la voiture
- Lancer le logiciel de communication
- Coupez le contact (et non moteur, juste l'allumage seulement)
- Sélectionnez le calculateur vous voulez lecture / écriture à partir d'une liste
- Sélectionnez des options supplémentaires (si nécessaire)
- Cliquez sur le bouton d'écriture et sélectionnez le fichier que vous voulez écrire
- Suivez les instructions à l'écran
- Couper le contact et attendre 10 secondes
- Fait.
http://www.obd2warehouse.fr/category-83-b0-Programmeur-De-Calculateur.html
Je ai mis mes KWP2000 plus écus Remap Flasher de obd2warehouse.fr. Il est venu avec un mini CD, contenant son logiciel. Le vendeur a déclaré le logiciel doit être installé sur XP. Je ne ai aucun problème d'installation sur un ordinateur XP et je ai ensuite réussi à utiliser sur mon ordinateur portable Windows 7 en utilisant VM ainsi. Hooked on jusqu'à ma voiture quelques minutes après l'arrivée et reconfiguré mon écus. Il a travaillé comme il se doit.
Voici un processus rapide à propos de flashage écus avec KWP2000:
- Brancher le matériel sur le port USB de l'ordinateur portable et le port de diagnostic de la voiture
- Lancer le logiciel de communication
- Coupez le contact (et non moteur, juste l'allumage seulement)
- Sélectionnez le calculateur vous voulez lecture / écriture à partir d'une liste
- Sélectionnez des options supplémentaires (si nécessaire)
- Cliquez sur le bouton d'écriture et sélectionnez le fichier que vous voulez écrire
- Suivez les instructions à l'écran
- Couper le contact et attendre 10 secondes
- Fait.
http://www.obd2warehouse.fr/category-83-b0-Programmeur-De-Calculateur.html
dimanche 20 septembre 2015
Lexia3 Citroën / Peugeot diagnostic outil d'installation instruction
Nous savions que Lexia-3 est une interface de diagnostic professionnel Citroën et Peugeot, il est à la fois la fonction facile utiliser et puissant. De nombreux clients achètent cet outil de diagnostic de eobd2.fr et peuvent faire face certains installent des problèmes, laissez-moi vous dire les étapes de configuration pour éviter ces problèmes.

À propos de Lexia-3 PP2000 Interface
http://www.obd2warehouse.fr/Lexia-3-Lexia-3-V47-PP2000-V25-for-Citroen-Peugeot-Diagnostic-Tools-646.html
Lexia-3 interface peut non seulement lire le code de défaut comme autre outil de scanner, mais aussi lire l'identification, auto-scan, vallées mesurées, test de l'actionneur, etc. compatible avec les voitures Citroën y compris: C1, C2, C3, C4, C6, C8 , C-CROSSER, NEMO, BERLINGO, JUMPY, JUMPER, AX, SAXO, BX et ainsi de suite, et il a également compatible avec la plupart des voitures Peugeot de 1995.
Eobd2.fr Lexia3 PP2000 Citroen/Peugeot diagnostic interface de mise à jour maintenant vers la dernière version: Lexia-3: V46, PP2000: V23, multi-langue disponible.
Lexia3 Citroën / Peugeot outil de diagnostic PP2000 configuration instruction
1. Instruction avant l'installation:
PP2000 V21 est le logiciel pour Peugeot!
Cliquez sur 'InstPC' installer
Lexia3 V45 est le logiciel pour Citroën!
Cliquez sur 'Instlex3' installer
Se il vous plaît créer un fichier txt vide nommé 'version' dans C: \ avant l'installation du Lexia3.
2. étapes de configuration Instruction:
A. Installez le logiciel. Avant l'installation, le système de fenêtres doit être anglais, et jusqu'à ce que dans le choix de la langue lors de l'installation du logiciel, vous êtes libre de choisir votre langue maternelle.
B. Activation du logiciel.
Sous le fichier "LEXIA3_KEYGEN", il ya les images d'activation pour lexia3 et le fichier "PP2000_KEYGEN" contient les images d'activation pour PP2000.
Conseils:
1. Il faut code enregistré pour PP2000, mais aucun code inscrit pour lexia3, comme pour le code enregistré.
2. Pour les clients dont la langue maternelle ne est pas l'anglais, ce est ok, car il ya 20 sortes de langue pour Citroën et 26 sortes de langue pour Peugeot.
AVIS: Avant l'installation, vous devez fermer tous les logiciels anti-virus, pour empêcher les données de l'appareil est détruit par le logiciel anti-virus.
À propos de Lexia-3 PP2000 Interface
http://www.obd2warehouse.fr/Lexia-3-Lexia-3-V47-PP2000-V25-for-Citroen-Peugeot-Diagnostic-Tools-646.html
Lexia-3 interface peut non seulement lire le code de défaut comme autre outil de scanner, mais aussi lire l'identification, auto-scan, vallées mesurées, test de l'actionneur, etc. compatible avec les voitures Citroën y compris: C1, C2, C3, C4, C6, C8 , C-CROSSER, NEMO, BERLINGO, JUMPY, JUMPER, AX, SAXO, BX et ainsi de suite, et il a également compatible avec la plupart des voitures Peugeot de 1995.
Eobd2.fr Lexia3 PP2000 Citroen/Peugeot diagnostic interface de mise à jour maintenant vers la dernière version: Lexia-3: V46, PP2000: V23, multi-langue disponible.
Lexia3 Citroën / Peugeot outil de diagnostic PP2000 configuration instruction
1. Instruction avant l'installation:
PP2000 V21 est le logiciel pour Peugeot!
Cliquez sur 'InstPC' installer
Lexia3 V45 est le logiciel pour Citroën!
Cliquez sur 'Instlex3' installer
Se il vous plaît créer un fichier txt vide nommé 'version' dans C: \ avant l'installation du Lexia3.
2. étapes de configuration Instruction:
A. Installez le logiciel. Avant l'installation, le système de fenêtres doit être anglais, et jusqu'à ce que dans le choix de la langue lors de l'installation du logiciel, vous êtes libre de choisir votre langue maternelle.
B. Activation du logiciel.
Sous le fichier "LEXIA3_KEYGEN", il ya les images d'activation pour lexia3 et le fichier "PP2000_KEYGEN" contient les images d'activation pour PP2000.
Conseils:
1. Il faut code enregistré pour PP2000, mais aucun code inscrit pour lexia3, comme pour le code enregistré.
2. Pour les clients dont la langue maternelle ne est pas l'anglais, ce est ok, car il ya 20 sortes de langue pour Citroën et 26 sortes de langue pour Peugeot.
AVIS: Avant l'installation, vous devez fermer tous les logiciels anti-virus, pour empêcher les données de l'appareil est détruit par le logiciel anti-virus.
S'abonner à :
Messages (Atom)


